A generated hardware comparison headed "3B active versus 25B active", with a Sage-Med-Preview card showing one GPU icon and the lines "35B total / 3B active" and "1 x H200, BF16", and a LingSante-3.1-flash card showing four GPU icons and the lines "560B total / ~25B active" and "4 x H20-3e, MXFP4". A footer reads "The closest rival either model has". The OrcaRouter logo is composited bottom-right.
Engineering & Research

Sage-Med-Preview vs LingSante-3.1-flash: 3B vs 25B Active

Author

jinhao.song

Date Published

Models in this article · 1View all models →
Back to all posts

This is the closest thing either model has to a real rival, and the difference that decides most deployments is not on a benchmark table. Sage-Med-Preview activates 3 billion of its 35 billion parameters per token, and the vendor's recipe fits it on a single H200. LingSante-3.1-flash activates roughly 25 billion of 560 billion and needs about 292 GiB of MXFP4 weights across four H20-3e cards, or roughly 574 GB of FP8 weights across eight H200s. Both are open-weight medical models released in November 2026. One is a specialist you can run on one card; the other is a frontier-scale system with a medical post-training pass. The general models around the specialist can sit behind one endpoint with automatic failover, so a single provider outage does not stop the surrounding workflow.

That gap shapes everything else: what each model is good at, what evidence each vendor publishes, and which one a hospital can actually put behind a queue by Friday.

The active-parameter gap, in hardware

Parameter counts are marketing until you translate them into memory and cards. Here is the translation.

• Sage-Med-Preview — 35B total, 3B active, 40 layers, 256 routed experts with 8 active per token. The published vLLM recipe runs BF16 at tensor parallel size 1 on one H200, with 0.85 GPU memory utilisation and a 32,768-token limit.

• LingSante-3.1-flash — 560B total, roughly 25B active, 72 layers split between 63 K​imi Delta Attention linear layers and 9 gated MLA layers, 512 routed experts plus one shared expert, 8 routed experts active per token. The MXFP4 build is about 292 GiB; the FP8 build is about 574 GB.

• Cards — one H200 versus four H20-3e or eight H200, depending on the quantisation.

• Rough compute per token — LingSante-3.1-flash activates a little over eight times as many parameters as Sage-Med-Preview. That is not a direct throughput ratio, because attention layers, batching and memory bandwidth all intervene, but it sets the order of magnitude.

• Cost sketch — at a nominal $2 per GPU-hour, the four-card LingSante node is about $8 per hour before utilisation. The single-H200 Sage-Med host is about $2 per hour. Neither vendor publishes tokens per second, so treat these as capacity estimates, not cost-per-request figures.

This is one of the few medical-model comparisons where the smaller model is not automatically the budget option. A 3B-active model at a single card can be cheaper per request than a 25B-active model at four cards even if the larger model is faster per token.

A screenshot of the Sage-Med project page headed "Sage-Med: Scaling Medical Multimodal Intelligence" with the 35B-A3B subtitle and panels showing a 58.3 average over 31 public benchmarks, 60.7 on report generation, 41.5 on medical visual grounding and 57.7 on private multi-center benchmarks.

What the two cards actually measure

Here is the uncomfortable fact: the two model cards do not share a single benchmark number. Not one row overlaps. A table comparing them would be fiction, so the honest move is to list what each vendor chose to measure and what that choice reveals.

Sage-Med-Preview reports 31 public medical multimodal benchmarks, a 58.26 average, and a long table spanning visual question answering, report generation, visual grounding and held-out clinical tasks. The rows include OmniMedVQA 95.54, MIMIC-CXR ROUGE-L 33.37, MedFrameQA 65.52, MedSG-Bench mIoU 31.73 and MMMU Pro-Med 74.48. The panel is image-heavy by construction, because the model is image-heavy by construction.

LingSante-3.1-flash reports text-heavy medical and agentic scores: HealthBench Professional 65.72, MedQA-USMLE 94.50, MedXpertQA-Text 57.27, EHR-Complex 74, HLE with tools 72.22, SWE-bench Pro 65.25, Terminal-Bench 4.0 at 26.5 and GDPval-AA at 1,600 Elo. Its one independent score is 23.3% on MLCR-AA, a long-context medical reasoning benchmark. The panel is text-and-tools by construction, because the model is text-only.

So the two cards are not competing measurements. They are advertisements for different jobs. Sage-Med-Preview is telling you it can see; LingSante-3.1-flash is telling you it can reason over records and operate tools.

A generated two-column scoreboard titled "Sage-Med-Preview vs LingSante-3.1-flash — the scoreboard". The Sage-Med column reads "Total params: 35B", "Active params: 3B", "Hardware: 1 x H200", "Context: 32,768 served", "Licence: none stated" and "Independent score: none"; the LingSante column reads "Total params: 560B", "Active params: ~25B", "Hardware: 4 x H20-3e", "Context: 262,144 shipped", "Licence: MIT" and "Independent score: 23.3 MLCR-AA". A footer reads "No benchmark appears on both cards; figures vendor-reported unless marked." The OrcaRouter logo is composited bottom-right.

Where LingSante is the stronger bet

If your work is text, the larger active model has the better case.

• Clinical reasoning over notes and guidelines — HealthBench Professional 65.72 and MedQA-USMLE 94.50 are strong vendor numbers, and the model was trained for exactly this.

• Agentic and tool-heavy workflows — SWE-bench Pro 65.25, Terminal-Bench 4.0 at 26.5 and GDPval-AA at 1,600 Elo describe a model that can operate a harness, not just answer a question. That is unusual in a medical specialist.

• Long documents — the card claims 1M tokens. The shipped configuration documents 262,144, so treat 1M as a ceiling that has not been demonstrated in the released setup.

• Licence clarity — MIT, with an MXFP4 build that makes the model deployable on a smaller node than the FP8 checkpoint would require.

• Independent signal — one outside score exists, 23.3% on MLCR-AA. It is low, but it is a real third-party measurement and it gives you something to calibrate against.

The catch is that all of this is text. LingSante-3.1-flash cannot read a chest film, a pathology slide or a fundus photograph. If your data is pixels, it is the wrong model no matter how good the reasoning scores are.

Where Sage-Med is the stronger bet

If your work is imaging, the smaller model is the only one of the two that does the job at all.

• Modality breadth — the evaluation covers more than 40 medical modalities, from radiography to fundus imaging to surgical video frames.

• Report generation — 33.37 ROUGE-L on MIMIC-CXR and 53.20 RaTEScore on CheXpert Plus, both ahead of GPT-6.2-Sol in the vendor's table.

• Visual question answering — OmniMedVQA 95.54 and SLAKE 88.11 are the strongest rows in its table.

• Deployment simplicity — one H200, one vLLM process, a 131 GiB download and a 32K context. No tensor parallelism, no multi-node orchestration.

• Cost floor — 3B active parameters is a genuinely small decode budget. Even without a published throughput number, the hardware entry point is a fraction of LingSante's.

The catch on this side is grounding. MedSG-Bench mIoU is 31.73 against 58.83 for GPT-6.2-Sol. If your task depends on drawing an accurate box around a lesion, this is not the model's strongest mode, and the 58.26 average does not show that weakness.

A screenshot of the LingSante-3.1-flash Hugging Face files page showing 228 likes, an MIT licence tag, a 574 GB repository, 54 safetensors shards, and tags for fp8, bailin_hybrid and custom_code.

The licence and context caveats

Two caveats sit above every benchmark in this piece.

The first is licensing. LingSante-3.1-flash ships under MIT. Sage-Med-Preview ships with no licence field on the Hugging Face card, no LICENSE file in the GitHub repository and no weights licence in the paper — the only licence text in the release covers the arXiv paper, not the model. MIT lets you deploy; an absent licence does not. For a hospital pilot, that difference outweighs several benchmark points.

The second is context. Both cards advertise more than their serving recipes deliver. Sage-Med-Preview's config declares 262,144 positions, but its published vLLM command caps the model at 32,768 and no evaluation goes beyond that. LingSante-3.1-flash's card claims 1M, while the released configuration documents 262,144. In both cases, the honest number is the one in the serving config, and the larger number is a capability claim awaiting a published long-context evaluation.

There is also a hardware caveat specific to LingSante. The MXFP4 build is the one that fits four H20-3e cards; the FP8 build needs eight H200s. A team that benchmarks on the small build and deploys the large one is comparing two different systems.

How to choose without a shared benchmark

You cannot settle this with a table, so settle it with four questions.

• What is the input? Pixels, scans, slides or video frames point to Sage-Med-Preview. Notes, guidelines, claims and tool calls point to LingSante-3.1-flash. If the answer is "both," you need a pipeline, not a model choice.

• What is the volume? A single-card deployment has a hard ceiling. If you are processing a health system's imaging backlog, model the queue before the benchmark.

• Can you legally deploy it? MIT versus no licence is a binary gate. Sage-Med-Preview may be testable and still not deployable.

• What will you measure yourself? Build a 100-case set from your own data, with your own scoring, and run both. Neither vendor's card can substitute for that.

OrcaRouter does not serve either model; both are self-hosted open weights. The routing layer matters for the work around them. A clinical product usually pairs a specialist with a general model for extraction, summarisation and interface text, and those general models are the ones we carry behind one key at provider list price with no markup added. The specialist stays on your card; the surrounding traffic does not have to.

If you have to choose today and you have one H200, the decision is easy: Sage-Med-Preview is the only one of the two you can run. If you have a four-card node and your problem is text, LingSante-3.1-flash is the more capable system and the cleaner licence. The hard case is the team with both kinds of data and neither kind of certainty — and for that team, the right first purchase is an evaluation set, not a GPU.